Mashinani kesish qobiliyati
Element | Model | Torch kabelining uzunligi | Hozirgi | Ish aylanishi | Pirs qalinligi | Ishlab chiqarishni kesish qalinligi | chetini kesish qalinligi |
1-5134-3 | CNCAM HP100 | 10m | 100A | 100% | 22 mm | 20 mm | 35 |
| CNCAM HP100 | 15m | 100A | 100% | 22 mm | 20 mm | 35 |
1-5134-3 | CNCAM HP100 | 10m | 100A | 100% | 22 mm | 20 mm | 35 |
1-5136-3 | CNCAM HP100 | 15m | 100A | 100% | 22 mm | 20 mm | 35 mm |
| Quyosh shamoli HP120 |
|
|
|
|
|
|
1-1134-3 | Quyosh shamoli HP160 | 10m | 160A | 100% | 30 mm | 25 mm | 50 mm |
1-1136-3 | Quyosh shamoli HP160 | 15m | 160A | 100% | 30 mm | 25 mm | 50 mm |
1-1334-3 | Quyosh shamoli HP200 | 10m | 200A | 100% | 32 | 30 mm | 60 |
1-1334-3 | Quyosh shamoli HP200 | 15m | 200A | 100% | 32 | 30 mm | 60 |
1-1334-3 | Quyosh shamoli HP260 | Nazorat jadvali | 260A | 100% | 38 mm | 32 mm | 70 mm |
1-1336-3 | Quyosh shamoli HP300 | Nazorat jadvali | 320A | 100% | 38 mm | 32 mm | 70 mm |
Ogohlantirish
Ushbu foydalanish bo'yicha ko'rsatmalar tajribali operator uchun tayyorlangan.Arkni payvandlash va kesish uskunasining ishlashini yaxshi bilishingiz kerak.
Iltimos, o'qimaydigan ishchilarni o'rnatishga yo'l qo'ymang.Ishlamoq.Ushbu uskunaga texnik xizmat ko'rsatish.
Agar siz ushbu ko'rsatmalarni tushuna olmasangiz, qo'shimcha ma'lumot uchun yetkazib beruvchi bilan bog'laning.
Ushbu mashinani o'rnatish va ishlatishdan oldin, iltimos, yuqoridagi xavfsizlik va eslatmalarni o'qing.
Foydalanuvchining javobgarligi
O'rnatish uchun faqat qo'lda ko'rsatmalarga muvofiq.ishlatish va texnik xizmat ko'rsatish.Uskunalar ushbu qo'llanmada va unga biriktirilgan teglarda tavsiflangan ishlashga erisha oladi.Uskunani muntazam tekshiruvdan o'tkazish kerak;Ishlamay qolganda yoki yomon parvarishlangan uskunadan foydalanmaslik kerak.Komponentlarda biron bir shikastlanish, yo'qotish, aşınma, deformatsiya yoki ifloslanish bo'lsa, darhol almashtirilishi kerak.Ta'mirlash yoki ehtiyot qismlarni almashtirish zarurligini tasdiqlash uchun telefon yoki yozma distribyutorlar orqali bog'laning.
Ishlab chiqaruvchining yozma ruxsatisiz, iltimos, uskunani yoki biron bir qismni o'zgartirish ruxsatisiz STH qilmang.Uskunaning foydalanuvchisi noto'g'ri foydalanish, noto'g'ri texnik xizmat ko'rsatish, shikastlanish, noto'g'ri texnik xizmat ko'rsatish yoki ishlab chiqaruvchi bo'lmagan yoki boshqa ko'rsatilgan xizmat ko'rsatuvchi tashkilot tomonidan har qanday nosozliklarni keltirib chiqarishi uchun to'liq javobgarlikni o'z zimmasiga olishi kerak.
O'rnatish va ishlatishdan oldin, o'zingizni va boshqalarni himoya qilish uchun ushbu qo'llanmani o'qib chiqing va tushuning.
Mahsulot tavsifi
Kirish
Hai bo plazma generatori yuqori tezlikda plazma kesish va boshqalar uchun mo'ljallangan, boshqa kompaniyalarning uskunalari bilan birgalikda ishlatilishi mumkin.
· kesish elektr diapazoni sozlanishi mumkin
· majburiy havo bilan sovutish
· qattiq holatdagi doimiy quvvat
· Kirish kuchlanish himoyasi
· Sensorli ekranni boshqarish
· asosiy transformator va yuqori quvvatli yarimo'tkazgich komponentlarini himoya qilish
· Yuk tashish uchun yuqori ko'taruvchi ushlagich yoki asosiy forklift joyi
Umumiy spetsifikatsiya
HP/100/160/200/260 380V/400V/ 50/60Hz | ||
Chiqish (100% ish aylanishining uzluksiz tezligi) | Kuchlanish | DC200V |
Kiritish | DC elektr diapazoni (kesish) | 15A~260A |
Quvvat | 2-72 kVt | |
* (OCV) | DC360V | |
kuchlanish (3 faza) | 380/400 dyu 380 / 400V | |
Chastotasi | 50/60 Gts | |
KVA | 91,6 KVA | |
Quvvat | 82,5 kVt | |
Quvvat omili | 90,0 % |
Hajmi va vazni
vazn = 82 kg
O'rnatish
Ochiq quti
3.1 Ochiq quti
● Mashina kelganda, shikastlangan yoki yo'qligini darhol tekshiring.
● Konteynerdan olib tashlangan barcha komponentlar va idishning qismlari tarqoq yoki yo'qligini tekshiring.
● Panjurlarda havo oqimining to'siqlari bor yoki yo'qligini tekshiring.
3.2 Saqlash
● Sovutish havosi oqimi uchun old va orqa kamida 1 metr (3 fut) bo'sh joy.
● Tom va yon panelni parvarishlash uchun olib tashlash uchun .tozalang va reja tuzing.
● HP quvvatining joylashuvi tegishli sug'urta bilan quvvat manbaiga nisbatan yaqin bo'lishi kerak
● Quvvat ostida saqlang, sovuq havo oqimi uchun hech narsa yo'q.
● Atrof-muhit uchun chang yo'q.tutun va qizib ketish.Bu sabablar sovutish samaradorligiga ta'sir qiladi.
3.3 Quvvatga ulanish
Ogohlantirish
O'liklarga elektr toki urishi mumkin!
Iltimos, maksimal elektr toki urishidan himoya qiling.
Mashinada har qanday ulanishni tugatishdan oldin, simni aylantiringit devordagi izolyatsiya kaliti elektr ta'minotini kesish uchun o'chiriladi.
3.4.1 Asosiy quvvat
HP quvvati uch fazali o'rnatishdir.Kirish quvvati kontaktlarning zanglashiga olib (devorda) izolyatsiyalangan kalit bilan ta'minlanishi kerak;mahalliy va davlat qoidalariga muvofiq sug'urta yoki o'chirgichni o'z ichiga oladi.
* Tavsiya etilgan kirish simi va elektron sug'urta spetsifikatsiyasi
Nominal yuk kiritish ostida |
| Kirish hidoyat chizig'i va topraklama simi *cooper/mm2(Amerika sim o'lchagich) | Vaqtni kechiktiruvchi sug'urta spetsifikatsiyasi (A) |
v | A | ||
380 | 140 | 50 (1) | 200 |
400 | 132 | 35 (2) | 150 sekin erish + 10%/-0 |
Tegishli yuk 200V 360A chiqishi
* Xususiyatlar Amerikaning "Milliy elektr kodeksi" ga muvofiq, 40 ℃ (104 daraja) haroratda 90 ℃ (194 daraja) mis simlarni ishlatadi.
Kabel trubkasi yoki simi ichida uchta simdan ko'p bo'lmasligi kerak.Agar mahalliy kodlar spetsifikatsiyalarda ko'rsatilgan va yuqoridagilardan farq qilsa, mahalliy kodlarga amal qilish kerak.
Kirish oqimining keng doiradagi chiqish mezonlarini baholash uchun quyidagi formuladan foydalaning:
Kirish elektr | (V yoyi) x (I yoyi) x 0,73 |
(V sxemasi) |
Izoh
Maxsus elektr tarmog'idan foydalanish kerak bo'lishi mumkin.
HP quvvat liniyasi kuchlanishni qoplash qobiliyatiga ega, ammo kontaktlarning zanglashiga olib keladigan haddan tashqari yuklanishi tufayli shikastlanishning oldini olish uchun ishlashga zarar etkazish.maxsus kuch ishlatish kerak.
3.4.2 Kirish bo'yicha ko'rsatma
· Mijozlar tomonidan yetkazib beriladi
· Qalin kauchuk qoplamali mis simlar uchun (uch ildizli elektr tarmog'i va tuproqli sim) yoki qattiq yoki moslashuvchan quvurli simlar bilan.
· Spetsifikatsiyalarni aniqlash uchun jadvalga muvofiq
3.4.3 Kirish ulanish tartibi
Ogohlantirish
Noto'g'ri topraklama shaxsiy shikastlanishga olib kelishi mumkin
Mashina ramkasi tasdiqlangan elektr topraklama liniyasiga ulanishi kerak.Topraklama simining hech qanday terminalga ulanmaganligini aniqlang
3.5Ochiqish ulanishi
Ogohlantirish
O'liklarga elektr toki urishi mumkin!Chiqarilgan qopqoq plitasining plazma quvvat manbaidagi xavfli kuchlanish va oqim
1. Elektr ta'minotini uzish uchun chiziqda (devorda) ajratuvchi kalit
2. Malakali xodimlarga chiqish shinasini (musbat va salbiy) aniqlash uchun voltmetrdan foydalanishiga ruxsat bering.
3.5.1 Chiqish kabeli (mijoz tomonidan taqdim etiladi)
400 Ann chiqish oqimiga asoslanib, 4/0 AWG (AWG) 600 v izolyatsiyalangan mis sim kerak
Aeslatma:
100 v izolyatsiya manba kabelidan foydalanmang.
4.0 ishlaydi
HP quvvat manbai diagrammasi HP
4.1.1 Boshqaruv tizimi asosiy menyu
A - Parametrlarni sozlash
Ark kuchlanish balandligini sozlash bilan bog'liq parametrlarni o'rnating
B - boshq kuchlanishini sozlash
boshq kuchlanish balandligini sozlash bilan bog'liq parametrlar dinamik monitoring
C - mutaxassis rejimi
Standart parametrni tanlash varaq qalinligi bo'yicha Sozlamalar
D - plazma parametri
Plazma kesish bilan bog'liq sozlamalar
E - Statistika
F - nosozliklarni bartaraf etish
nosozlik tavsifi va yechimini aniqlash uchun joriy tizimni tekshiring
G - vaqt sozlamalari
Mashina soati sozlamalari
Statistik kesish vaqti va pirsing raqamlari
H - IO diagnostikasi
kirish/chiqish IO port funksiyasini tekshiring
4.1.2 Parametr sozlamalari interfeysi
1. Maksimal kesish tezligi: mm / min
Dvigatelning ishlashi sozlamalariga ko'ra, agar uyqu rejimida bo'lsa, 1000-2000 - mm / min oralig'ida o'rnatilishi mumkin.Plazma kesish eng yaxshi 3000 mm / min dan ortiq o'rnatiladi.5 mm vintni o'rnatish 3500-4000 - mm / min mos keladi.
2. Boshlanish tezligi: mm/min
Umumiy sozlamalar taxminan 150-400 - mm / min.
3. Qo'l harakati tezligi: mm / min
Yuqoriga va pastga tugmachalarning harakat tezligini bosing, odatda qo'l harakati tezligi kichikroq, aniq joylashishni aniqlash oson, umumiy sozlamalar taxminan 800-1500
4. Tezlikni tezlashtirish:
Yuqoriga va pastga tugmachalarning harakat tezligini bosing, umumiy qo'l harakat tezligi kichikroq, aniq joylashishni aniqlash oson, Umumiy sozlamalar taxminan 800-1500
5. Puls ekvivalenti:
Mobil ishora qiladi 1 mm qancha puls yuborish kerak, Bu sozlash va nozik vint pitch va tegishli hisoblash usuli bilan vosita ball.Bir inqilob puls ekvivalenti = kerakli impulslar soni/pitch.
6. Kesish balandligi
Dastlabki pozitsiyaning kesish balandligi
7. Joylashuv datchiklari masofasi:
Sensor ma'lum bir javob masofasiga ega bo'lganligi sababli, joylashishni aniqlash masofasini aniq belgilash kesish balandligini aniqroq belgilashi mumkin.
8. Ark kuchlanishini kalibrlash
Kesuvchi nozullarning shikastlanishi tufayli yoy kuchlanishi va balandlikni sozlash parametrlari aniq emas,
9. Burilish nuqtasi oqimi nisbati:
Oqimning burilish nuqtasi ulushini kamaytirish uchun belgilangan nisbatga ko'ra, ko'krakni yoqish hodisasidan saqlaning
4.1.3 Ark kuchlanish sozlamalari interfeysi
Interfeys real vaqt rejimida alohida monitoring, 380 v kuchlanish, havo bosimi, boshq kuchlanishi, oqim va harorat.Muammo mavjud bo'lsa, real vaqt rejimida xato diagnostikasi tahlil qilinadi.
O'ng tomonda, yoy kuchlanishi va elektrni kesish, nuqta ma'lumotlarining markaziy holatida raqamli klaviatura sozlamalari paydo bo'ladi, shuningdek, biroz sozlash uchun "+"、'-' tugmasi orqali ham mumkin.
Kesuvchi qurolni yuqoriga va pastga siljitish uchun ↑、↓ tugmasini bosing.
4.1.4 Plazma parametri sozlamalari interfeysi
●Arkni puflash vaqti: MS birligi (1s = 1000ms)
Kesishni boshlash uchun, birinchi navbatda, puflash uchun, agar quvur liniyasi juda uzun bo'lsa, bu parametr kattaroq o'rnatilishi kerak, gazning kesish holatiga erisha olmasligi, plazma yoyi hosil bo'lmasligi, kesish mash'alining shikastlanishi.
● Puflash kechiktirilganda
Kesish tugagach, sovitish puflash uchun kesish quroli, nozullar va sarf materiallarini berish uchun bu zarbani oxirgi marta o'rnating.
● Arkni puflash vaqti
Qachon yuqori chastotali yoy belgilangan vaqt.Muvaffaqiyatli ateşleme to'plamini iloji boricha kafolatlashi mumkin bo'lgan parametr ostida, bu elektrodni kesish nozulining xizmat qilish muddatini uzaytirishi mumkin.
● Politsiya harorati haqida xabar berdi
Harorat signalini o'rnatish ustidagi plazma issiqlik moslamasi, Displey signal interfeysi
● kuchlanish chegarasiga
Asosiy plata harorat signalini o'rnatishdan ko'ra ko'proq, Displey signal interfeysi
300 dan pastga o'rnatilgan bo'lsa, kamon paydo bo'lmasligi mumkin
Umumiy sozlamalar 320 v dan ortiq, bu parametrdan pastroq, ba'zi nosozliklar paydo bo'ladi yoki kesish qobiliyati yomon.
● Eng kichik gaz bosimi
Oddiy atmosfera bosimi 4 dan 6 psi gacha.Plazma yoyi boshlang'ich havo bosimi odatda 10-20 psi bo'lsa yaxshi bo'ladi, 45 dan 60 PSI gacha kesishda PSI to'plamidan past bo'lsa, signalga xabar beradi.
● nozulni almashtirish uchun bitta tugma
100 a suv tabancasi Bu funksiyasiz, lekin bir tugmani bosib, ko'krakni tozalash vaqtini va kesish vaqtini nolga o'zgartirishi mumkin.
suv tabancası birinchi navbatda nasos va elektromagnit klapanning ishlashini to'xtatib, kesish uchun mash'alaga havo puflaydi, sovutish suvi tankga qaytariladi.Jarayondan so'ng, sovutish suvi yo'qotilishiga yo'l qo'ymaslik uchun chiqib ketish nozulini o'zgartiring.Shu bilan birga, perforatsiya soni va kesish vaqti qayta o'rnatiladi, ko'krakni o'zgartirish uchun bitta kalit tugadi.
nozulni almashtirish uchun bitta kalit har qanday ishni to'xtatish uchun asosiy transformator sxemasini bajaradi, operatorni elektr toki urishiga yo'l qo'ymaydi.
●Tizim diagnostikasi
Chiqish tugmachasini bosing, mos keladigan chiqish portining indikator chirog'i yoqish va o'chirish funktsiyasiga ega bo'ladi, shu bilan birga, asosiy platada mos keladigan indikator ham ishlaydi.Bu sinov portidan foydalaning yaxshi yoki yomon.
Agar indikator nuri va displey boshqacha bo'lsa, u chiqish qismida muammo borligini e'lon qiladi
5.0 Xizmat
5.1 Umumiy
Ogohlantirish
Elektr toki urishi halokatli bo'lishi mumkin!
Har qanday ta'mirlash ishlarini bajarishdan oldin, elektr ta'minotini uzib qo'yish uchun chiziqni (devor) ajratuvchi kalitdan foydalaning
Ogohlantirish
Tozalash uchun siqilgan havodan foydalaning, ko'zlarga zarar etkazish xavfi mavjud.
1. Tozalash quvvati paytida ko'zni himoya qilish uchun ruxsat berilgan yon qopqoqni taqing.
2. Faqat past bosimli havodan foydalanish mumkin.
Diqqat
Ushbu uskunaga texnik xizmat ko'rsatish faqat o'qitilgan xodimlar tomonidan amalga oshirilishi kerak.
5.2 Toza
Elektr ta'minotining muammosiz ishlashiga yordam berish uchun muntazam tozalashni amalga oshirish kerak.Tozalash chastotasi atrof-muhit va foydalanishga bog'liq.
1. Elektr ta'minotini o'chirish uchun devordagi izolyatsiyalash tugmasi
2. Ikki yon panelni echib oling.
3. Suvsiz past bosimdan foydalaning Siqilgan havo barcha havo kanali va uning qismlari changini olib tashlash uchun.Ayniqsa, radiatorning old qismidagi quvvat manbaiga e'tibor berish kerak.Chang kesiladi va issiqlikni kamaytiradi.
Iltimos, ko'zni himoya qilish vositalarini kiying.
Diqqat
Havo oqimi chegarasi HP quvvatining haddan tashqari qizib ketishiga olib kelishi mumkin.
Hermal kalit harakat qilishi va ishni to'xtatishi mumkin.
Ushbu uskunani havo filtri ishlatib bo'lmaydi.
Havo kanalida chang va boshqa to'siqlar bo'lmasligi kerak.
Elektr toki urishi bilan zararlang.
Quvvatni yoqishdan oldin har qanday qopqoqni orqaga o'rnatganingizga ishonch hosil qiling
6.0 Nosozliklarni bartaraf etish
6.1 Nosozliklarni bartaraf etish bo'yicha kirish
Muammolarni topish uchun alomatlar bo'yicha orqadagi muammolarni bartaraf etish bo'yicha qo'llanmaga murojaat qiling.Davolash usullari juda oddiy bo'lishi mumkin.Agar sabablarni tezda aniqlay olmasangiz, kirish quvvatini uzing, oddiy vizual tekshirish uchun barcha komponentlar va simlarni quvvat manbaini oching.Terminal ulanishining mustahkamligini, simlar va komponentlarning uzilgan yoki yonib ketganligini tekshiring.
Muammoning sababini nazorat qilish operatsiyalar ketma-ketligiga murojaat qilish orqali amalga oshirilishi mumkin.Elektr sxematik diagrammasi va topish uchun tegishli qismlarni tekshiring.Tekshirishning bir qismi v ohmmetrdan foydalanish uchun zarur bo'ladi.
6.2 Nosozliklarni bartaraf etish bo'yicha qo'llanma
quvvat manbai yoqilganda, displeyda bir soniya davomida EP ko'rinishi kerak, so'ngra Pr 3.01 yoki undan yuqoriroq kabi dastur kodini ko'rsatishi kerak.Displey har doim bo'sh bo'lsa,
Quyidagi holatlar bor yoki yo'qligini tekshiring:
a.Asosiy boshqaruv paneli va displey paneli o'rtasida bo'shashgan yoki etishmayotgan kabel mavjud
b.Yo'q + 15 v egilish kuchlanishi, bu F1 yoki F2 sug'urta birlashmasidan kelib chiqishi mumkin
c.Old panelda CB1 elektron to'xtatuvchisi ochiq.
Agar dastur kodidan keyin quvvat manbai Xato (5-xato) 5 ni ko'rsatsa, ishga tushirish tugmasi yopiq yoki yo'qligini tekshiring.Elektr ta'minotini qayta o'rnatmoqchi bo'lsangiz, ochish uchun kalitni bosing.Bu vaqtda displeyda ikkita Windows 0 bo'lishi kerak. Agar quvvat manbai yoqilgan bo'lsa-da, lekin CNC ga ulanmagan bo'lsa, ichki quvvatning favqulodda to'xtash rölesi (K4) elektr tokiga ega bo'lmasa, quvvatning o'zi hech qanday rele harakatini qilmaydi.
Agar CNC ishga tushirilgan bo'lsa, volt va amper ko'rsatkichlari displeyda 0 bo'lishi kerak. 115-dagi asosiy quvvat tanlash kirishida (J1 H igna) va simli ulanishdan oldin kirish (kirishni tanlash uchun asosiy quvvat manbai) bo'lsa, bu qurilma boshlash signaliga javob bermayapti.Ushbu ulanish cnc ning asosiy quvvat kabeliga javobgar bo'lishi kerak.E'tibor bering, cnc kirishdan tortib, barcha o'rni yopiq, izolyatsiya plitasigacha (quvvat manbai ichida 4-bosma plita) ac115 kirishini ta'minlang.Izolyatsiya plitasi bu kirishlarni chiqish uchun ochiq kollektorga aylantiradi.Ushbu boshqaruv bo'sh rejimda va shartlar bajarilmaganda va noto'g'ri ko'rsatmalar berganda bir nechta signallarni kuzatib boradi: 1, 3, 4, 5, 9 yoki 12 xato (6.3 "yordam kodi" ro'yxatiga qarang).
Kalit yoqilganda va kesishni tayyorlashda kesish quvvati ba'zi qo'shimcha shartlarni kuzatib boradi.Natijada paydo bo'lgan xato holati: 2, 6, 8, 12, 13, 14, 15, 17, 18, 19 yoki 113 ("yordam kodi" ro'yxati 6.3 bo'limiga qarang).
6.3 Nosozliklarni izolyatsiya qilish
6.3.1 Fan ishlamayapti
Muammo | Mumkin sabablar | To'g'ri choralar |
Uchta fan ham ishlamaydi | Bu kesilmaganda normal hodisa.Fan faqat "kontakt" signalini qabul qilganda ishlaydi | holda |
1 yoki 2 fan ishlamayapti | Fan motorining davrlari shikastlangan yoki singan simlar | Ta'mirlash simi |
muvaffaqiyatsiz fan | Fanni almashtiring |
7.0 Zaxira qismlar
7.1 Umumiy
Iltimos, har doim komponentlarning (ishlatiladi) birligining seriya raqamini ko'rsating.Seriya raqami qurilmaning nom plaketida bosilgan.
7.2 Sotib olish
Oddiy ishlashni ta'minlash uchun uskunadan faqat ESABning original qismlari va mahsulotlaridan foydalanish tavsiya etiladi.ESAB tomonidan ta'minlanmagan qismlardan foydalanish texnik xizmat ko'rsatishni bekor qilishi mumkin.
Zaxira qismlarni ESAB dilerlaridan buyurtma qilish mumkin.
Zaxira qismlarga buyurtma berishda, etkazib berishning maxsus talablari mavjudligiga ishonch hosil qiling.
Agar sizga mijozlarga xizmat ko'rsatish telefon raqami kerak bo'lsa, iltimos, ushbu qo'llanmaning orqa qopqog'idagi aloqa qo'llanmasiga qarang.
EPP-360 ma'lumot kuchi | |
Qism raqami | EPP-360, CCC/CE, 380 / 400v, 50 / 60Hz |